BIRNS Penetrators are generally wired according to the following conductor color coding:

Conductor Number

Conductor Background (Base) Color

First Tracer (Stripe) Color
Second Tracer Color
Conductor Number

Conductor Base Color

First Tracer Color
Second Tracer Color
1

Black

---
---
31

Green

Black
Orange
2

White

---
---
32

Orange

Black
Green
3

Red
(Green color when in 3-conductor cable.)

---
---
33

Blue

White
Orange
4

Green

---
---
34

Black

White
Orange
5

Orange

---
---
35

White

Red
Orange
6

Blue

---
---
36

Orange

White
Blue
7

White

Black
---
37

White

Red
Blue
8

Red

Black
---
38

Black

White
Green
9

Green

Black
---
39

White

Black
Green
10

Orange

Black
---
40

Red

White
Green
11

Blue

Black
---
41

Green

White
Blue
12

Black

White
---
42

Orange

Red
Green
13

Red

White
---
43

Blue

Red
Green
14

Green

White
---
44

White

White
Blue
15

Blue

White
---
45

White

Black
Blue
16

Black

Red
---
46

Red

White
Blue
17

White

Red
---
47

Green

Orange
Red
18

Orange

Red
---
48

Orange

Red
Blue
19

Blue

Red
---
49

Blue

Red
Orange
20

Red

Green
---
50

Black

Orange
Red
21

Orange

Green
---
51

White

Black
Orange
22

Black

White
Red
52

Red

Orange
Black
23

White

Black
Red
53

Green

Red
Blue
24

Red

Black
White
54

Orange

Black
Blue
25

Green

Black
White
55

Blue

Black
Orange
26

Orange

Black
White
56

Black

Orange
Green
27

Blue

Black
White
57

White

Orange
Green
28

Black

Red
Green
58

Red

Orange
Green
29

White

Red
Green
59

Green

Black
Blue
30

Red

Black
Green
60

Orange

Green
Blue
Rev. 090624

BIRNS Penetrators with neoprene (polychloroprene) cable jackets are rated to 80°C (176°F) (max.). BIRNS Penetrators with CSPE cable jackets are rated to 95°C (203°F) (max.).